Pultruded FRP Online Market
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Brand Name : GOLDEN

Model Number : HLWH-360DM-630DM

Certification : CE

Place of Origin : Guangdong

MOQ : 1pcs

Price : Negotiable

Payment Terms : T/T, Western Union, L/C, MoneyGram

Supply Ability : 500pcs per month

Delivery Time : 10 working days after received your payment

Packaging Details : Wooden Case

Cooling capacity(KW) : 358-632

Power supply : 380v-50hz-3ph

Heating capacity(KW) : 387-675

Condenser : Ripple Aluminum Fins Around Copper Pipe

Certificate : CE

Mount type : free standing

Chilled water flow(m³/h) : 61.6-108.7

Contact Now

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Model HLWH~

360DM

390DM

460DM

490DM

540DM

590DM

630DM

Rated Cooling

Capacity

Cooling

Capacity (KW)

358

391

464

490

536

586

632

Comp.

Input Power (KW)

116.4

127.6

141.0

148.2

164.8

180.4

197.8

Rated Heating

Capacity

Heating

Capacity (KW)

387

423

491

518

569

622

675

Comp.

Input Power (KW)

114.4

125.6

138.3

145.4

161.7

176.9

194.4

Refrigerant

R407C

Power Supply

380V/ 3ph/ 50Hz

Safety Protection

Phase reversion protection,

Phase lack protection,

Overload current protection,
Discharge air temp. protection,

Low & High pressure protection,

Low temp. protection,

Water flow protection.

Number of

Refrigeration Circuit

2

Capacity Control (%)

0, 25, 37.5, 50, 62.5, 75, 87.5, 100

Refrigerant Charge (Kg)

114

122

146

150

164

178

196

Air Cooled

Heat Exchanger

Ripple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger

Dia.of Pipe (inch)

5"

5"

3"×2

3"×2

4"×2

4"×2

4"×2

Water Side

Max Pressure (MPa)

1

Chilled

Water Flow(m3/h)

61.6

67.2

79.8

84.3

92.2

100.8

108.7

Water

Pressure

Drop (kPa)

42

54

44

52

54

55

65

Flow of

Hot Water(m3/h)

66.6

72.7

84.4

89.1

97.9

107.0

116.1

Axial Fan

Air Flow×1000m3/h

172.8

172.8

230.4

230.4

230.4

321.6

321.6

Power×Qty (KW)

1.2×12

1.2×12

1.2×16

1.2×16

1.2×16

2.0×16

2.0×16

Running Noise dB(A)

75

75

75

75

75

75

75

Total Weight (Kg)

5620

5800

6240

6430

6600

6960

7320

Running Weight(Kg)

6040

6280

6680

6850

7100

7460

7960

1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃

Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW.

2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃

Hot water inlet/outlet temp. 40℃/45℃; Hot water range: 45℃~45℃;

2. Chilled Water Range: 5~20℃; Lowest Ambient Temperature: -5℃~43℃;

3. Heat recovery unit water in/out temperature: 50℃/55℃;

4.Changes of Specification for lmprovement May Be made without Notice.

Feature :

Flexible configuration

The unit and tank flexible configuration.A different water tank to choose,pressure or open type connected to

meet the different demands of clients.

Environment Friendly

Using refrigerant 407C or 410A, no damage,environment friendly.

Simple operation

Intelligent design, LCD display, simple operation, free setting during 30 ° c - 60° c and cycle timing set

on/off freely.

Quiet running

Using efficient, low-noise rotary, closed scroll compressors and low-noise fan,ensure quiet running.

Working environment

Applicable to -15°C~45°C- the outdoor harsh environment temperature, all-weather work.

Wide application

Widely used for room radiant, floor heating, schools, factories, apartments, sauna, SPA association, beauty

salon, fitness center, guesthouse, hotel, hospital, senior residential, swimming pool, factories, farms,

greenhouse production process etc, can replace the fuel gas boiler and heating boilers, water equipment etc.

Modular design

Multi-modular units adopt module combined structure to increase unit’s flexibility in transportation, installation,

adjustment and maintain and reduce fee for transportation, installation and equipment maintain.

Unit protection components

The units have thermal protection switch, overload relay, high/low pressure switch, paddle flow switch and

delay-starting protection devices to ensure unit runs under safety, reliable working condition and unit is easy to

maintain and repairing.


Product Tags:

Air Cooling Units

      

Modular Air Cooled Chiller

      
Buy cheap Flexible Type Air Cooled Water Chiller Heat Pump Environment protection product

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Pultruded FRP Online Market
*Subject:
*Message:
Characters Remaining: (0/3000)